This glycol-only trunk line contains two 3/8" I.D. polyethylene tubes inside an insulated bundle with a taped outer jacket. It connects the glycol power pack to the cooling circuit in a commercial draft beer system, providing separate supply and return paths.
One tube carries chilled glycol towards the equipment being cooled, while the other returns it to the power pack for re-chilling. Keeping both tubes insulated helps limit heat gain along the route.
Built for Glycol Recirculation
The red and blue tubes make the two circulation paths easier to identify during installation and service. Their 3/8" inside diameter must suit the pump, fittings and flow requirements of the system.
The complete route matters when selecting a recirculation line. Longer runs, elevation changes and additional connections affect circulation resistance and should be considered when sizing the pump.
Insulation and Taped Jacket
Approximately 3/4" (19 mm) of foam insulation surrounds the tubes to help reduce heat entering the coolant. A taped outer jacket covers and protects the insulated assembly.
Insulate and seal exposed tubing and connections at both ends. Support the bundle without crushing the foam or forcing sharp bends, which can restrict flow and damage the insulation.
Key Benefits
- Two glycol lines: Provide separate supply and return paths.
- 3/8" I.D. tubing: For cooling circuits designed around this line size.
- 19 mm foam insulation: Helps limit heat gain along the installation route.
- Red and blue tubes: Help identify circulation connections.
- Taped outer jacket: Protects the insulated bundle during handling and installation.
Specifications
- Glycol lines: 2
- Glycol tubing inside diameter: 3/8" nominal, approximately 9.5 mm
- Glycol tubing material: Polyethylene (PE)
- Tube identification: Red and blue
- Insulation material: Foam
- Insulation thickness: Approximately 3/4" (19 mm)
- Outer jacket: Taped
- Application: Glycol supply and return connections in commercial draft beer cooling systems
Selecting the Right Recirculation Line
Confirm the required length, tubing diameter and connection sizes before ordering. Match the circulation pump and glycol chiller to the cooling load and resistance of the complete installation.
Browse our glycol trunk lines to compare configurations, or email our team for help selecting the right assembly.
Important Note for US Customers Ordering Trunk Line Shipped from Canada
Lengths over 20–30 ft may require palletized shipping, depending on the trunk line’s diameter and the size of the finished coil. Longer lengths of smaller-diameter trunk line may fit in standard shipping boxes, but packaging must be confirmed for each order.
For shipments requiring customs clearance, the carrier or customs broker may request your business tax ID. You may also need to complete CBP Form 5106 and provide supporting documentation if your importer information is not already registered with US Customs.
Note: This glycol trunk line is sold by the foot (1 ft = 0.3048 m), with a minimum order of 10 ft. It is cut to order and non-returnable. Exposed glycol tubing and connections should be properly insulated and sealed.
For selection assistance or a shipping quote, email our team at sales@beveragecraft.com with your required length and full delivery address. Ships from Canada.